What size generator do you need to run a house?
Your loads set the generator size, not square footage. Add the running watts of everything on at once, then the largest single start-up surge (EWEB). A gas-heated 1,500 sq ft house came to 3,830 running and 6,030 starting watts. An all-electric one with a heat pump hit 21,130 starting watts, so manage loads.
Key facts
| Fact | Value | Source |
|---|---|---|
| The sizing rule | Total the running watts, then add the one highest additional starting figure | Eugene Water & Electric Board (EWEB) |
| Refrigerator/freezer | 700 running watts plus 2,200 additional starting watts | EWEB |
| Furnace fan blower, 1/3 HP | 700 running watts plus 1,400 additional starting watts | EWEB |
| Central A/C, 3 ton, or electric heat pump | 6,000 running watts each, starting factor of 3 | DTE Energy |
| Electric water heater | 4,500 watts (EWEB); 4,500 to 5,000 watts for a 50-gallon tank (DTE) | EWEB |
| Motors at start-up | Most motorized appliances need more than their electrical rating to start | Honda EU2200i owner's manual |
| Where a portable generator runs | Outside only, at least 20 feet away from the house; more than 80 CO deaths a year in the US | CPSC |
How big of generator do you need to run a house?
The generator you need is set by the loads you run at the same time, and a house can need anywhere from about 6,000 to more than 30,000 starting watts. Two utilities, EWEB and DTE Energy, publish worksheets that give the method.
Square footage does not appear in either worksheet. A 1,500 sq ft house with a gas furnace and a 1,500 sq ft house with a heat pump are different jobs. The worked examples below show the gap with real arithmetic.
Where your appliance label gives a number, use it in place of the table figure.
What is the difference between running watts and starting watts?
Running watts are the steady power an appliance draws once it is going. Starting watts are the brief surge a motor needs to get going, and the surge can be a multiple of the running load.
Honda’s manual says most motorized appliances need more than their electrical rating to start. EWEB lists the extra as “additional starting watts.” A refrigerator/freezer is 700 running watts plus 2,200 additional starting watts, so the peak is 2,900 W for a few seconds.
DTE uses a starting factor instead. A factor of 3 means the start-up draw is three times the running watts. DTE gives a refrigerator/freezer a factor of 3, a furnace fan a factor of 3 and a central A/C a factor of 3.
Resistive loads such as a water heater, a toaster or a space heater have no start-up surge on either worksheet.
How do you calculate what size generator to run a house?
List what you will run at once, total the running watts, then add the largest single starting surge. That is EWEB’s method, and it gives two numbers to compare with a generator’s rating.
- List the loads. Pick only what you will run in the same hour.
- Find each running figure. Use the appliance label first. Multiply volts by amps to get watts, as DTE’s worksheet says. Use a utility table when there is no label.
- Add the running watts. This is your running total.
- Pick the highest additional starting watts. EWEB adds only this one item, because in most cases one motor starts at a time.
- Add it to the running total. This is your starting total.
- Compare with the generator. Honda’s manual says the electrical rating of what you connect must not exceed the rated power of the generator. Check the rated figure against your running total and the maximum figure against your starting total.
Honda’s sizing page agrees that “it is not necessary to power everything at the same time.” Its example staggers a refrigerator and a furnace fan so their start-ups do not overlap. That cuts the starting need by 1,600 W in its numbers.
What size generator runs a 1,500 sq ft house with gas heat?
A gas-heated 1,500 sq ft house on winter essentials works out to 3,830 running watts and 6,030 starting watts. The gas furnace still needs its fan blower, so the blower counts.
This is a made-up household to show the method. The wattages are from EWEB’s reference guide.
| Load | Running watts | Additional starting watts |
|---|---|---|
| Refrigerator/freezer | 700 | 2,200 |
| Furnace fan blower, 1/3 HP | 700 | 1,400 |
| Ten LED bulbs, 15 W each | 150 | none listed |
| Phone charger (20) and laptop (60) | 80 | none listed |
| Color TV | 400 | none listed |
| Microwave, 1,000 W | 1,000 | none listed |
| Sump pump, 1/3 HP | 800 | 1,300 |
| Running total | 3,830 | |
| Highest additional start (refrigerator) | 2,200 | |
| Starting total | 6,030 | 3,830 + 2,200 |
Check the sums: 700 + 700 + 150 + 80 + 400 + 1,000 + 800 = 3,830. Then 3,830 + 2,200 = 6,030.
Look for a generator rated at 3,830 W or more running and 6,030 W or more maximum. Spec sheets list a rated figure and a higher maximum. Honda’s EU2200i, for example, is rated 1.8 kVA (1,800 VA) with an overload alarm above 2.2 kVA (2,200 VA). Those are volt-amps, and Honda’s manual tells you to add up your total power requirements in VA. Watts and VA match for resistive loads like lights and a microwave. Motors draw more VA than watts, so check the amps on the label for fridge, pump and fan loads. Compare your running total with the first number and your starting total with the second.
Drop the microwave and the running total falls to 2,830 W. If you never run the sump pump, that pump’s 800 W comes off too. In a winter outage, a gas house does not need central A/C. In summer, swap the furnace fan for the A/C line in the next section.
A well pump, if you have one, is a further 1,000 running and 2,000 additional starting watts for a 1/3 HP pump on EWEB’s list. The fridge still sets the largest start at 2,200 W, so the running total rises to 4,830 W and the starting total to 7,030 W (4,830 + 2,200).
How many watts does an all-electric 1,500 sq ft house need?
An all-electric 1,500 sq ft house with a heat pump needs between 9,130 and 20,880 running watts, depending on what else runs. Starting watts run from 21,130 to 32,880 on DTE’s factors.
The same base load applies, minus the furnace fan, because a heat pump has no separate gas furnace blower in this model. The heat pump and A/C figures are from DTE: 6,000 running watts and a starting factor of 3. That makes the additional start 2 × 6,000 = 12,000 W, bigger than the refrigerator’s 2,200 W. The water heater is EWEB’s 4,500 W. The range burner is DTE’s large burner at 2,400 W, and the clothes dryer is DTE’s 4,850 W.
| Tier | What runs | Running watts | Highest additional start | Starting total |
|---|---|---|---|---|
| Base | Fridge 700, lights 150, chargers 80, TV 400, microwave 1,000, sump pump 800 | 3,130 | 2,200 | 5,330 |
| A: base + heat pump | Base plus 6,000 | 9,130 | 12,000 | 21,130 |
| B: A + water heater | Adds 4,500 | 13,630 | 12,000 | 25,630 |
| C: B + one burner and dryer | Adds 2,400 and 4,850 | 20,880 | 12,000 | 32,880 |
Check the sums: 700 + 150 + 80 + 400 + 1,000 + 800 = 3,130. Add 6,000 for tier A: 9,130. Add 4,500 for tier B: 13,630. Add 2,400 and 4,850 for tier C: 20,880. Starting totals are the running total plus the highest additional start.
A heat pump is not the only way to get here. A central A/C in a gas house uses the same 6,000 W and the same factor of 3. A gas house running its A/C on a hot-weather outage lands on the tier A numbers.
The factor of 3 is DTE’s planning rule. The nameplate or your installer has the real start-up figure for your unit. DTE’s worksheet notes that a heat pump or central A/C has a starting wattage above its GenerLink device’s 40-amp capacity.
Load management is how people run an electric house on a smaller generator: switch the water heater, burner and dryer on only while the heat pump is off. Calculate each combination you will allow as its own total, including its largest additional start. The base plus a dryer and a burner, for example, is 3,130 + 4,850 + 2,400 = 10,380 running watts, above tier A’s 9,130.
Does square footage tell you what size generator to run a household?
Square footage is a weak proxy, because the two 1,500 sq ft examples above differ by more than three times. What drives the number is the heat source, central A/C, water heating, cooking and pumps.
Many seller guides publish a watt range per house size. Those ranges can’t know whether your furnace is gas, whether you have a well, or whether you want the dryer. The worksheet method needs only a list and a label.
| Same 1,500 sq ft | Running watts | Starting watts |
|---|---|---|
| Gas heat, winter essentials | 3,830 | 6,030 |
| All-electric, heat pump only (tier A) | 9,130 | 21,130 |
| All-electric, heat pump, water heater, burner and dryer (tier C) | 20,880 | 32,880 |
Use square footage for nothing more than a sanity check on your finished list.
Can a generator run a whole house?
A generator can run a whole house if its rating covers your totals and it is connected to the house wiring by a qualified electrician. A cord to individual appliances is the other route.
Honda’s manual says connections to a building’s electrical system must be made by a qualified electrician, and the connection must isolate the generator from utility power. It warns that a wrong connection can backfeed into utility lines, which may electrocute utility workers, and that the generator may explode, burn or cause fires when utility power returns. The two standard hardware choices are compared in interlock kit vs transfer switch.
Carbon monoxide (CO) comes before any wiring choice. CPSC says more than 80 consumers die each year from CO poisoning caused by portable generators. It says to run a portable generator outside only, at least 20 feet away from the house, with the exhaust pointed away. Never run one in a home, garage, basement, crawlspace, shed or on a porch, even with doors and windows open. The distance rules are on how far a generator should be from the house.
For a list of what a given size actually powers, see what a generator can run. If the first thing you need is the fridge, see what size generator runs a refrigerator. For gas heat on a smaller battery unit, see running a gas furnace on a portable power station. For the first hours of an outage, see what to do when the power goes out.
Decision checklist
- List only the appliances you will run in the same hour.
- Write each running watt figure from the appliance label (volts × amps). Fall back to the utility tables.
- Add the running watts. This must fit under the generator’s rated output.
- Pick the one highest additional starting figure and add it to the running total. This must fit under the maximum output.
- Start motors one at a time.
- Check whether you have an electric heat source, central A/C, a well pump or a sump pump. Add each one you have: electric heat and A/C add thousands of watts, a sump pump adds 800.
- Run the generator outside, 20 feet from the house, exhaust pointed away.
- Have an electrician make any connection to the house wiring.
Frequently asked questions
How many watts do I need to run a house?
It depends on what runs at once. In the worked examples below, a gas-heated 1,500 sq ft house on essentials needs about 3,830 running watts and 6,030 starting watts. An all-electric house running a heat pump needs about 9,130 running watts and 21,130 starting watts on the utility's figures.
What size generator do I need to run a 1,500 sq ft house?
Square footage does not set the answer. The two 1,500 sq ft examples on this page differ by more than three times, because one heats with gas and the other with a heat pump. List your own appliances and total them.
Do I add up the starting watts of every appliance?
EWEB's worksheet adds only the single highest starting figure to the total running watts. This works if you let one motor start at a time. DTE's worksheet says only items that start at the same moment should be tallied together.
Can I plug a generator into my house?
Honda's manual says connections to a building's electrical system must be made by a qualified electrician and must isolate the generator from utility power. A wrong connection can backfeed into utility lines and electrocute line workers. Use a cord to the appliances you need until it is done properly.
Should I buy a generator based on running or starting watts?
Both must clear your totals. The rated or running output must cover your running load. The maximum or starting output must cover your running load plus the biggest start-up surge.
Sources
- Generator Sizing Considerations, Eugene Water & Electric Board (EWEB) (accessed 2026-10-26)
- Appliance Usage Guide and GenerLink Worksheet, DTE Energy (accessed 2026-10-26)
- EU2200i / EU2200i Companion Owner's Manual, Honda Power Equipment (accessed 2026-10-26)
- How much power do I need?, Honda Power Equipment (accessed 2026-10-26)
- What to Know About Generators and Carbon Monoxide (CO), leaflet CPSC468, U.S. Consumer Product Safety Commission, 2022-03 (accessed 2026-10-26)